TS610 Electromagnetic Flowmeter
TS610 Electromagnetic Flowmeter
TS610 Electromagnetic Flowmeter (the electromagnetic flowmeter) is a smart metering instrument developed and manufactured using advanced international technology. It features high accuracy, reliability, stability, and long service life. DANRUI emphasizes every process, including construction, materials, manufacturing, assembly, and testing. Utilizing the 37 m water tower as a stabilizing device for flow calibration and a specialized production line for mass flowmeter. Additionally, dedicated software and hardware were developed for the mass production, ensuring sustained high standards. It is widely used in oil, chemicals, metallurgy, water supply and drainage, steel, coal, papermaking, food, textiles, and environmental protection.
TS610 Electromagnetic Flowmeter
Advantage
• Accuracy unaffected by fluid density, viscosity, temperature, pressure, or conductivity.
• No obstructing parts, no pressure loss.
• Simple construction, easy installation, minimalstraight pipe section required.
• No mechanical inertia, fast response, goodlinearity, suitable for pulsating flow.
• Sensor lining and electrodes contact themedium; proper materials ensure corrosionand wear resistance for long-term use.
• Multi-electrode design for high accuracy, nogrounding ring needed, reducing costs.
• EEPROM stores specs and total flow dataduring power off.
• The transmitter utilizes low-powerconsumption single-chip microcomputer, withreliable performance, high accuracy, andstable zero. Dot-matrix LCD displays totalflow, instant flow, flow velocity, flow percentage.
• Two-way measurement, supports positive andnegative flow; low-frequency excitationimproves stability and low-flow performance
• Integrated pressure measurement, simultaneous flow and pressure reading
Features
| Diameter | Flanged DN3 ~ DN2400 |
| Hygienic DN6 ~ DN50 | |
| Threaded DN6 ~ DN50 | |
| Wafer DN10 ~ DN300 | |
| Accuracy | Class 0.5, 0.2 |
| Electrode types | Standard fixed electrode, anti-fouling electrode |
| DN6 ~ DN20 one pair of measuring electrodes, no grounding electrode | |
| DN25 ~ DN500 one pair of measuring electrodes and one pair of grounding electrodes | |
| ≥DN600 two pairs of measuring electrodes and one pair of grounding electrodes | |
| Construction types | Integral, remote (remote cable length ≤ 99m) |
| Explosion-proof mark | Ex db ib mb IIC T6 Gb |
| Rated pressure | GB: PN2.5, PN6, PN16, PN25, PN40, PN63, PN100, PN160, PN250, PN320 |
| ANSI: CLASS 150, CLASS 300, CLASS 600, CLASS 900, CLASS 1500 | |
| DIN: PN10, PN16, PN25, PN40, PN63, PN100 | |
| JIS: 5K, 10K, 16K, 20K, 30K, 40K, 63K | |
| Others: Custom-made | |
| Electrode | 316L, Titanium (Ti), Hastelloy (HB, HC), Tantalum (Ta), Tungsten carbide (WC), Platinum -iridium (Pt), Ceramic |
| Lining | Chloroprene rubber (CR), Natural rubber (NR), Polyurethane rubber (PU) |
| Polytetrafluoroethylene (PTFE), F46, PFA, Ceramic | |
| Meter tube | 304 SS |
| Flange and body | Carbon steel, 304 SS, 316L SS |
| Transmitter housing | Cast aluminum, 304 SS |
| Power supply | 220VAC |
| 12V DC, 24V DC | |
| Battery-powered (with LCD display, RS485 output, wireless output, frequency/pulse output – frequency/pulse output for calibration only) | |
| Output signal | 4mA ~ 20mA DC (load resistance 0Ω ~ 750Ω, active output) |
| HART output | |
| Frequency/pulse output (optional passive or active) | |
| Upper and lower limit alarm output | |
| RS485 output (ModBus protocol), RS232 output | |
| Profibus-DP, Profibus-PA | |
| Electrical port | M20×1.5 (Female), NPT 1/2 (Female) |
| IP rating | IP65: Dust proof, protected against water jets IP67: Dust proof, protected against temporary immersion IP68: Protected against continuous immersion (sensor part only |